Recovery of 4.2 MWh Through Proactive Detection of Thermal Derating
Discover how Delfos helped recover 4.2 MWh of energy by remotely identifying and resolving a case of thermal derating in a solar inverter with fan failure. Predictive analysis and actual performance.
Delfos remotely identified a ventilation system failure in a solar inverter, preventing ongoing energy losses and operational risks — all resolved with a simple corrective action.
Context
During routine monitoring, Delfos’ Performance Engineering team detected an anomaly in the performance of a solar inverter, which showed consistently lower generation compared to nearby units with the same rated power.
A key detail about this plant is that it does not have a SCADA system, meaning the Delfos Platform is essential for operational visibility and monitoring. In this context, Delfos acts as the client's primary tool for diagnostics and performance insights.
Upon analyzing the inverter’s time-series behavior using Delfos, the team identified a pattern consistent with thermal derating: power limitation due to internal overheating.
Figure 1. Timeseries active power with limited inverter
Implemented Solution
Using the Delfos Platform, the team:
Compared generation curves of similar inverters and identified performance discrepancies;
Noticed that INV07 consistently limited its output during periods of higher irradiance;
Correlated this behavior with repeated “Overtemperature” alarms registered in the platform;
Shared the issue during a performance review meeting with the client and recommended a field inspection by the O&M team.
During the on-site inspection, the O&M team found that two out of three cooling fans were not operational, causing the inverter to overheat and limit output throughout the day.
“Non-functioning fans in an inverter can, in the worst-case scenario, lead to fire and total equipment loss. Quick identification was crucial to mitigating this risk.” — Delfos Performance Engineer
After the faulty fans were replaced, the Delfos Platform confirmed that the inverter’s power curve and generation output returned to expected levels.
This quick and data-driven intervention not only prevented future energy losses but also eliminated the operational risk of catastrophic equipment failure.
Figure 2. Timeseries active power after fan replacement (operating normally)
Conclusion
Delfos proved to be a key enabler for proactive issue detection, especially in plants with limited on-site infrastructure. With the platform, the client was able to:
Detect abnormal inverter behavior remotely;
Act quickly and assertively based on reliable insights;
Implement a simple yet effective corrective action;
Prevent a high-risk operational incident;
Confirm full performance recovery after maintenance.
Highlights:
Energy Recovered: 4.2 MWh
Detection Period: 6 months of accumulated losses
Root Cause: Thermal derating due to failed cooling fans
Risk Avoided: Potential fire and total inverter loss
Full recovery confirmed via Delfos Platform
FAQ
What issue did Delfos detect in the solar inverter and why does it matter?
Industry problem: Inverter INV07 was consistently generating less energy than similar units because of thermal derating (power limitation due to overheating), creating hidden production losses and safety risk.
Delfos solution: The Delfos Platform remotely identified this underperformance pattern and linked it to repeated “Overtemperature” alarms. This allowed the O&M team to inspect the inverter, find non-functioning cooling fans, replace them, and recover 4.2 MWh while reducing the risk of fire and total inverter loss.
What is thermal derating in a solar inverter?
Industry problem: Thermal derating occurs when an inverter automatically limits its power output to protect internal components from overheating. This protects the hardware, but silently reduces generation and revenue if not detected quickly.
Delfos solution: Delfos continuously analyzes inverter time-series data and generation curves to flag patterns consistent with thermal derating. By surfacing these events in advance, the platform helps asset owners intervene before small thermal issues turn into long-term energy loss or equipment damage.
How can I detect thermal derating if my solar plant does not have SCADA?
Industry problem: Plants without SCADA lack centralized visibility, making it hard to spot subtle anomalies like one inverter underperforming compared to others with the same rated power.
Delfos solution: In this case, Delfos acted as the client’s primary diagnostic and monitoring tool, replacing the role of SCADA. The platform compared INV07 with nearby inverters, highlighted its lower production during high irradiance, and correlated this with overtemperature alarms, enabling the owner to detect thermal derating remotely and act with confidence.
How does the Delfos Platform identify abnormal inverter performance?
Industry problem: Traditional monitoring often misses performance drifts, such as one inverter consistently limiting output while others operate normally, resulting in long periods of unnoticed energy loss.
Delfos solution: Delfos combines comparative analytics and alarm intelligence to pinpoint the root cause:
Detecting inverter anomalies with and without Delfos
Aspect
Without Delfos
With Delfos Platform
Performance visibility
Underperformance may go unnoticed, especially without SCADA or detailed comparison tools.
Generation curves from similar inverters are compared side by side to reveal discrepancies.
Root cause detection
Operators see a production gap but often lack clues about why it is happening.
Overtemperature alarms and time-series behavior are correlated to flag thermal derating.
Actionability
Corrective actions are reactive and depend on sporadic field reports.
Delfos surfaces a clear issue for the O&M team, who can run targeted inspections and fix the root cause.
In the reported case, this data-driven workflow led directly to identifying failed cooling fans and restoring the inverter’s expected power curve.
What operational risks are associated with failed inverter cooling fans?
Industry problem: Non-functioning fans cause the inverter to overheat, forcing it to limit output throughout the day. In extreme cases, overheating can escalate to fire and total loss of the equipment, posing both safety and financial risks.
Delfos solution: The Delfos Platform quickly identified abnormal thermal behavior and repeated “Overtemperature” alarms. This early warning allowed the O&M team to replace two failed fans before any catastrophic event occurred, turning a high-risk situation into a simple maintenance task.
What measurable results were achieved with Delfos in this case?
Industry problem: Undetected thermal derating can accumulate over months, eroding plant performance and revenue, with no clear visibility of the real impact.
Delfos solution: In this project, Delfos enabled the client to:
Recover 4.2 MWh of energy that would otherwise be lost.
Address around 6 months of accumulated losses linked to the issue.
Eliminate the risk of potential fire and total inverter loss related to overheating.
Confirm through the platform that the inverter’s power curve and generation returned to expected levels after fan replacement.
This closed loop—from detection to validation—shows how Delfos converts data into tangible financial and operational gains.
How does Delfos support O&M teams in the field?
Industry problem: O&M teams often receive generic alarms without context, spending time on broad inspections instead of targeted, high-impact actions.
Delfos solution: Delfos’ Performance Engineering team used the platform to summarize the issue—thermal derating due to suspected cooling problems—and shared it during a performance review meeting with the client. With this clear guidance, the O&M team performed a focused field inspection, quickly identified two non-operational fans, implemented a straightforward replacement, and restored normal operation with minimal downtime.
When is Delfos most valuable for solar plants with limited on-site infrastructure?
Industry problem: Plants without SCADA or advanced on-site systems have blind spots in real-time performance monitoring, making it harder to justify and prioritize maintenance actions.
Delfos solution: Delfos becomes the central visibility and analytics layer for these assets. In the reported case, the platform replaced a missing SCADA solution by aggregating data, detecting abnormal behavior in INV07, and providing actionable insights that led to immediate corrective maintenance. This makes Delfos especially valuable for portfolios where on-site infrastructure is limited but reliability and performance expectations remain high.
How does Delfos validate inverter performance recovery after maintenance?
Industry problem: After maintenance, many operators rely on spot checks instead of continuous analytics to confirm that the issue is fully resolved, leaving room for residual underperformance.
Delfos solution: Once the faulty fans were replaced, the Delfos Platform tracked the inverter’s power curve and energy generation in real time. The data confirmed that the inverter was no longer limiting output during high irradiance and that its production aligned again with similar units. This evidence-based validation closes the loop, proving that the intervention effectively removed the thermal derating and recovered the expected energy yield.
How does Delfos turn early anomaly detection into reduced safety and equipment-risk?
Industry problem: Overheating issues may start as minor alarms but can escalate into severe incidents, including potential fire and complete inverter loss if they aren’t addressed quickly.
Delfos solution: By correlating overtemperature alarms with limited power output and historical patterns, Delfos identified the thermal derating early and quantified its impact. This prompted timely maintenance, removing the cause—failed cooling fans—before the equipment reached a critical state. As a result, the client not only recovered energy but also avoided a high-risk operational incident.
How can I start using Delfos to prevent thermal derating and hidden losses in my solar fleet?
Industry problem: Many solar portfolios suffer from unnoticed inverter issues—such as thermal derating, ventilation failures, and chronic underperformance—that gradually reduce returns and increase operational risk.
Delfos solution: By connecting your inverters to the Delfos Platform, you gain remote visibility, automated detection of abnormal behavior, expert performance engineering support, and post-maintenance validation. This combination helps you transform scattered data into clear actions that recover energy, extend equipment life, and protect your assets.
To explore how Delfos can be applied to your plants, you can request a tailored demo focused on your portfolio’s challenges.
Want to stop hidden thermal derating losses and gain full visibility of your inverters?